5-13
Troubleshooting
5
When the warning message is displayed
After nishing the online print, if any warning information exists, the following
warning message is displayed and the ERROR LED blinks.
Follow the message to resolve.
PE RFORM DAILY
MAIN TE NAN CE NOW
Meaning When the regular maintenance (cap cleaning) is not performed,
this message is displayed.
Resolution Perform the regular maintenance (cap cleaning).
( P.4-2 [Periodic maintenance])
SE R VIC E N EED ED
CA LL SER V ICE
Meaning This message is displayed when the life of supply tube pump
assembly nearly expires.
Resolution Contact your dealer or Seiko I Infotech for service of the supply
pump.
RE PLAC E
WI PER B LAD E
Meaning This message is displayed when the life of Wiper blade nearly
expires.
Resolution Execute [REPLACE WIPER BLADE]of PH.MAIN MENU and replace the
Wiper blade.
( P.4-21 [Wiper blade replacement])
RE PLAC E
WI PER S PON GE
Meaning This message is displayed when the life of Wiper sponge nearly
expired.
Resolution Execute[REPLACE WIPE SPONGE]PH.MAIN MENU and replace the
Wiper sponge.
( P.4-25[Wiper sponge replacement])