4-3
Maintenance and Adjustment / Replacement
4
(2) Check the remaining of wipe cleaning liquid
Open the Front cover and the Cap cover and
visually check the remaining wipe cleaning
liquid.
If the wipe cleaning liquid is empty, replace it.
( P.4-23 [Wiper cleaning liquid
replacement])
The wipe cleaning liquid needs replacement
about once a month as a general rule.
Regular Inspection / Maintenance (Daily maintenance)
To keep the print quality stable, perform the following six items in order of 1 to 6
described below.
(1) Check the Waste ink bottle : everyday
(2) Check the wipe cleaning liquid : everyday
(3) Check the stain on the Wiper blade : everyday
(4) Clean the Capping unit : every week
(5) Implementation of the head cleaning [normal] : every week
(6) Implementation of the nozzle print : everyday
Note
- Only use the Cleaning liquid, Cap cleaning stick, Cap cleaning roller or Cleaning
swab supplied by Seiko I Infotech.
(1) Check the Waste ink bottle
Check that the Waste ink bottle is not lled.
When the waste ink is lled to the level of
[FULL] label, replace the Waste ink bottle with
a new one.
( P.2-40 [Waste ink bottle replacement])