4-49
Maintenance and Adjustment / Replacement
4
Adjustment during operation
If the adjustment is left in the initial adjustment state, depending on this state of
media, the winding defect such as uneven wound may occur.
In this case, avoid the symptom by turning the adjustment screw on the plate
(left).
Counterclockwise
: The left side position
of Tension bar is lowered.
Clockwise
: The left side position
of Tension bar is raised.
<Right side>
<Right side>
By turning the adjustment screw on the
plate (left), adjust the position of Tension bar.
< Adjustment example >
When take-up, it shifts in the left direction.
(When viewed from the printer front)
The media is wound in the right direction.
Media
Media
Turn counterclockwise the
adjustment screw.
(The right side position of
Tension bar is lowered.)
Note
- Adjustment may be needed several times during a long print, depending on the
condition of the media.,
q Adjustment of take-up reel unit