21 Step Combination
W
W
K
K
_
_
_
_
_
_
W
W
K
K
_
_
_
_
_
_
W
W
K
K
_
_
_
_
_
_
S+ (solder pre-feed
amount)
CY 1 ON x.xx (iron tip
extend & pre-heat timer)
S+ (secondary solder feed)
S- (solder retract amount)
TIM (reflow timer)
CY1 OFF (retract iron tip)
End Condition
E
E
N
N
D
D
E
E
N
N
D
D
E
E
N
N
D
D
Work Parameter Settings
Group 01:
S+ Solder Feed Forward (amount)
S- Solder Feed Reverse (amount)
CY1 ON Extend Air Cylinder (timer)
CY1 OFF Retract Air Cylinder (timer)
TIM Timer (general use)
END End of Work Sequence
AIR Air Blow (tip cleaning timer)
ACK Slide Solder Timing Sequence
TEM Tip Temperature Setting (degrees)
Group 02:
OUT Output Signal (01 ~ 08 & duration
IN Input Signal (01 ~ 08) & duration
SET Turn On Output Signal
RST Reset Output Signal (turn off)
WST Wait for a Start Signal
JMP Jump to Alternate Program, continue
sequence without stopping
TE2 Second Temperature Setting “temp.
alarm Off)
LDS (x x) Turn on Laser Diode (wattage)
LDR Reset (turn off) Laser Diode
Sample Sequence:
S+ 2.5 25.0 Feed 2.5 mm of solder @ 25 mm / sec.
CY 1 ON 0.0 Tip Extend
TIM 0.5 Timer of 0.5 Seconds
S+ 3.0 10.0 Feed 3.0 mm of solder @ 10 mm / sec.
S- 3.0 25.0 Retract solder by 3 mm @ 25 mm/sec.
TIM 0.3 Solder dwell time after feed 0.3 sec.
CY 1 OFF Retract Iron Tip
END End of Sequence
Solder Parameter Solder WORK Profile Description Sheet (101, 102 & 103)
Explanation (Blocks 101~199 = Point Solder, Blocks 201~299 = Slide Solder, Blocks 301~399 = Special Condition)
Notes:
Tip Part #: Tip Temperature:
Work Data:
Comentários a estes Manuais