CMD_GETOPTIONS (1Dh) - Request option settings
This command is used to request the option settings. Normally, this is the value of
the option jumpers, but may be different if the options have been changed (e.g., by
the CMD_SETOPTIONS command). The printer will return a response byte with
a base value of D0h and the lower 4 bits set according to the following tables:
Parameter = 0 (Read jumpers 0-3)
Bit Jumper Meaning Bit Clear (0) Bit Set (1)
0 0 Baud rate (bit 0) * *
1 1 Baud rate (bit 1) * *
2 2 Feed mode Continuous Label / Form
3 3 Baud rate (bit 2) * *
* See baud rate table in CMD_SETOPTIONS section
Parameter = 1 (Read jumpers 4-7)
Bit Jumper Meaning Bit Clear (0) Bit Set (1)
0 4 (reserved) -- --
1 5 Auto power on Disabled Enabled
2 6 Media type Paper Label
3 7
Parameter = 2 (Read jumpers 8-11)
Bit Jumper Meaning Bit Clear (0) Bit Set (1)
0 8 (reserved) -- --
1 9 (reserved) -- --
2 10 (reserved) -- --
3 11 (reserved) -- --
Parameter = 3 (Read jumpers 12-15)
Bit Jumper Meaning Bit Clear (0) Bit Set (1)
0 12 (reserved) -- --
1 13 (reserved) -- --
2 14 (reserved) -- --
3 15 (reserved) -- --
Parameter =4 (Hardware Error Status)
Bit Meaning Bit Clear (0) Bit Set (1)
0 Temperature error No Yes
1 Supply voltage error (6V or 12V) No Yes
2 Head error No Yes
3 Voltage error (Vcc) No Yes