QC-6A
High accuracy
Highly stabilized quartz oscillator guarantees
remarkable precision for the whole system.
Large capacity
Up to 50 secondary clocks can be linked to the master
clock.
Flexible voltage transformer
No more voltage fluctuation thanks to a new power
supply circuit.
Built-in battery
Back-up power supply for the master clock.
Automatic re-adjustment
Even during power failure, all the secondary clocks are
driven by the optional battry unit B-450(stand-by
battery unit B-450 for secondary clocks optionally
available).
Accuracy and Synchronization of
Secondary Clocks
How to Drive Secondary Clocks
The role of the secondary clock in a time-keeping system is to
accurately reproduce the time signal supplied by the master
clock. The master clock and secondary clocks are connected
electrically, and the quartz oscillation frequency of 4.194304
MHz/sec. from the master clock is reduced in several stages
by the frequency diving LSI and finally transmitted to the
secondary clock as a 30-sec. polarized signal of ±24 V DC.
The secondary clock converts this electrical signal into
mechanical energy and, with the same precision as the master
clock, simultaneously displays the correct time.
AC/DC operation
Operates on either AC or DC power supply.
30sec. 30sec. 30sec.
2
MASTER CLOCK
CONTENTS SPECIFICATIONS
Accuracy
Within ±0.2 sec./day (+5℃∼+35℃)
Monitor
Analogue clock with second inidication
(Red LED)
Output
A : 30-sec. polarized for secondary clocks
B : 1-min. non-polarized for peripheral equipment
C : 1-sec. non-polarized for peripheral equipment
Output signals
A+B : 600mA
C : 10mA
Output capacity
A, B, C : 500ms
Pulse length
A, B : DC12V
C : Open collector
Output voltage
Power Supply
AC input
100∼250V±10%
Voltage selector“H”and“L”
DC input
22∼35V
Ripple : less than 1 V peak to peak, Max. 2A
Protector
Fuse provided
Built-in Battery
Guaranteed
duration
Battery
Indication of
power failure
During a power failure, the monitor clock, all
secondary clocks and LED lamp will stop.
They will be corrected automatically after
power is resumed.
Approx. 10∼12 hours
Ni-Cd
LED lamp off
Correction
of Time
Method
Automatic pulse control
Speed
30 times faster than nomal
Setting the Time
Manual
0 second setting swith provided
Dimensions
300(W)×320(H)×115 ( D ) mm
Weight
5.0kg